India Bio Fermenter – Welding & Structural Inspection,10 Types / 14 Equipment
Inspection was conducted on 3 days for 10 types and 14 equipments.During inspection, a case was found where PAD plates were reversed. The inspector decided on rework and re-inspection. The manufacturer explained that the issue did not affect performance and proposed to issue an NCR and handle it per internal quality procedures. Since the core purpose of inspection is to verify conformity between documentation (drawings, strength calculations, etc.) and the actual product, the
6일 전


Japan, KEA Inspection for Sterilizer.
산업 통상자원부고시로 진행된 설비이다. 검사에서 자재 동등성(Mill Sheets 화학적 성분) 확인 증빙자료가 요청되었다.