Italy, KEA inspection for Sterilizers, 4 Types and 10 Equipment
- YoungWoo Lee
- 5일 전
- 1분 분량
최종 수정일: 2분 전
이탈리아 베니스, 4종 10기, 멸균기 검사 보고서가 들어온다.
검사원 지적사항 및 검사 내용이 공유된다.(아래는 지적사항/ 권고 내용이다.)
Exhibit No.11 – Material Receiving/Picking Reports:Add a thickness verification field to the form and include a note at the bottom specifying tolerance information for thickness and dimension (ref. UG-16).

(4종 10기, 압력부품이 자재별로 구분 정리되어 검사 대기 중..)
Rectangular Shape:The height of the rectangular part was noticeably deformed. Steel support should be used to maintain the shape (ref. UG-80).
Drawing Revision:The following points need to be confirmed:
Missing dimensions of body and jacket (Width × Length × Height) on main drawing
Missing door joint (clamp) detail
Missing welding detail
Missing PT information on design data
Missing required capacity of safety valve on nameplate
Missing hydro test information on nameplate
구조검사는 12월 초 진행 예정이다.